Device guide · AV network switch

NETGEAR M4250-12M2XF: ports, specs and setup guide

The M4250-12M2XF is a compact 1U AV switch with twelve 2.5G multi-gigabit copper ports and two 10G SFP+ uplinks, and no PoE. Click any port on the panels below to see what it does, then read on for the specs, fan modes and uplink options.

  • 1U rack mount
  • 12 x 2.5G copper
  • 2 x 10G SFP+
  • No PoE
  • 100 Gbps fabric
  • MSM4214X
Rear panel, drawn to scaleInteractive
Switch - NETGEAR M4250-12M2XF (rear, 1U) OOB CONSOLE USB C OOB: RJ45 (plain jack) Console (RJ45): RJ45 (plain jack) Console (USB-C): USB-CUSB-C Port 1: RJ45 (plain jack) Port 2: RJ45 (plain jack) Port 3: RJ45 (plain jack) Port 4: RJ45 (plain jack) Port 5: RJ45 (plain jack) Port 6: RJ45 (plain jack) Port 7: RJ45 (plain jack) Port 8: RJ45 (plain jack) Port 9: RJ45 (plain jack) Port 10: RJ45 (plain jack) Port 11: RJ45 (plain jack) Port 12: RJ45 (plain jack) Port 13 (SFP+): SFP / SFP+ cageSFP+ Port 14 (SFP+): SFP / SFP+ cageSFP+ Power (C14): IEC C14 mains inlet
Front panel, drawn to scaleInteractive
Switch - NETGEAR M4250-12M2XF (front, 1U) USB storage (USB-A): USB-A LED Ext (USB-C): USB-CUSB-C
NETGEAR M4250-12M2XF back panel (all data ports) and front display panel. Click a port to identify it.
Get it in DaMatrix

M4250-12M2XF specifications

ModelM4250-12M2XF (order code MSM4214X, e.g. MSM4214X-100NAS in the Americas)
Form factor1U rackmount, only 100 mm (3.9 in.) deep, reversible mounting
Copper ports12 x 100M/1G/2.5G RJ45 (no PoE)
Uplinks2 x 1G/10G SFP+
Switching fabric100 Gbps non-blocking, 74.40 Mpps
Power1 internal PSU, C14 inlet with on/off switch
Management1G out-of-band port, RJ45 RS232 and USB-C consoles, USB-A storage
Dimensions (W x D x H)440 x 100 x 43.2 mm (17.3 x 3.9 x 1.7 in.)
Weight1.74 kg (3.85 lb)
Power draw37.9 W with all ports in use, 14.1 W standby
Heat output129.4 BTU/hr
Operating temperature32 to 122 F (0 to 50 C)
MTBF720,892 hours at 25 C

Every port on the back and front panels, explained

Click a card to light up those ports on the panels above.

12 multi-gigabit copper ports12 on the panel

Ports 1 to 12 run at 100 Mbps, 1 Gbps or 2.5 Gbps over RJ45, in three blocks of four.

These ports do not supply PoE, so powered devices need their own power or a PoE model in the series.

Out-of-band management port1 on the panel

The RJ45 port labeled OOB is a 1G service port. Patch it to a separate management network so you can reach the switch even when the AV VLANs are busy or misconfigured.

RJ45 serial console1 on the panel

The CONSOLE port is an RS232 serial connection on an RJ45 jack, wired straight-through, for local CLI access with a standard console cable.

USB-C ports2 on the panel

There are two USB-C ports. The one on the back, next to the console jack, is a second console port for a laptop. The one on the front display panel is labeled LED Ext.

USB-A storage port1 on the panel

The front USB-A port takes a flash drive for configuration backups, firmware images, logs and packet captures.

Power inlet1 on the panel

One internal power supply with a C14 inlet and an on/off switch, at the far end of the back panel. It takes a standard C13 mains cord.

Lights and buttons

  • Status LEDs: power and fan LEDs sit at the left of the back panel, with a recessed reset button below them, and are repeated on the front display panel.
  • Port LEDs: the front display panel mirrors a link light for every port, so you can check the switch from the front of the rack while the cabling stays at the back.
  • Clamp hole: the round threaded hole in the middle of the front panel is the M10 mount for clamps.

M4250-12M2XF fan modes and placement

At only 100 mm deep, the 12M2XF fits shallow wall racks and AV furniture where a full-depth switch won't.

Mode at 25 CConditionsNoise
Fan offUp to 4 ports at 2.5G in ports 1 to 6 and 4 in ports 7 to 12, no SFP+ in use0 dBA
QuietAny load28.5 dBA
Cool (fans at 100%)Any load55 dBA

It is rated for 0 to 50 C, a little higher than the PoE models in the series.

Compare the M4250 series

One datasheet covers 13 M4250 models. They share the same software, AV profiles and management ports, and differ in size, port mix and PoE budget.

ModelForm factorCopper portsUplinksPoE budget
M4250-9G1F-PoE+Desktop8 x 1G PoE+, 1 x 1G1 x SFP (1G)110 W
M4250-8G2XF-PoE+Desktop8 x 1G PoE+2 x SFP+ (1G/10G)220 W
M4250-10G2F-PoE+1U8 x 1G PoE+, 2 x 1G2 x SFP (1G)125 W
M4250-10G2XF-PoE+1U8 x 1G PoE+, 2 x 1G2 x SFP+ (1G/10G)240 W
M4250-10G2XF-PoE++1U8 x 1G PoE++, 2 x 1G2 x SFP+ (1G/10G)720 W
M4250-26G4F-PoE+1U24 x 1G PoE+, 2 x 1G4 x SFP (1G)300 W
M4250-26G4F-PoE++1U24 x 1G PoE++, 2 x 1G4 x SFP (1G)720 W (1 PSU), 1,440 W (2 PSU)
M4250-26G4XF-PoE+1U24 x 1G PoE+, 2 x 1G4 x SFP+ (1G/10G)480 W
M4250-40G8F-PoE+1U40 x 1G PoE+8 x SFP (1G)480 W
M4250-40G8XF-PoE+1U40 x 1G PoE+8 x SFP+ (1G/10G)960 W
M4250-40G8XF-PoE++2U40 x 1G PoE++8 x SFP+ (1G/10G)720 W to 2,880 W (1 to 3 PSU)
M4250-12M2XF1U12 x 100M/1G/2.5G2 x SFP+ (1G/10G)None
M4250-16XF1UNone16 x SFP+ (10G; first 12 also 1G)None

M4250 AV profiles and the AV web interface

Every M4250 ships pre-configured for audio and video over IP, so encoders and decoders can be plugged in and work without setup. IGMP Plus is on by default on VLAN 1, which keeps multicast video from flooding the network.

  • AV web interface: browse to the switch's IP address on port 8080 for the AV-specific settings. The regular IT web interface and a CLI are there too.
  • Audio profiles: Dante, Q-SYS, AES67 and AVB are built in.
  • Video profiles: NVX, AMX, Q-SYS, NDI, Kramer KDS, Aurora Multimedia, ZeeVee, Atlona, Dante, SDVoE and more, plus mixed audio, video and control profiles. Profiles are color coded and applied per port.
  • Switch-to-switch links: with Auto-Trunk and Auto-LAG, two M4250s connected together trunk their VLANs and bundle multiple links automatically.
  • Fleet management: the NETGEAR Engage controller manages M4250, M4300, M4350 and M4500 switches together.

M4250 management ports

All M4250 models share the same set of management ports, though where they sit (front or back) depends on the model.

  • Console: an RJ45 RS232 straight-through serial port and a USB-C console port, for local CLI access.
  • Out-of-band Ethernet: a 1G service port for a separate management network.
  • USB-A storage: for logs, packet captures, configuration files and firmware images.
  • Dual firmware: two firmware images and two configuration files, so updates cause minimal downtime.

Mounting and fan modes

  • Rackmount models can be mounted reversed when you want the ports facing the front of the rack. A second, included pair of ears sets the switch back 2 in. (about 5 cm) to leave room for cables.
  • Threaded holes underneath (4 x M5 on a 50 x 100 mm VESA pattern) and on the front (1 x M10 for clamps) allow mounting outside a rack.
  • Desktop models are meant for conference rooms, mobile studios, under a table or behind a screen, and mount with side flanges.
  • Fans are software controlled. Most models can switch the fans off entirely when the room temperature and PoE load are low enough, and offer Quiet and Cool modes otherwise. The M4250-9G1F-PoE+ is fanless.

Fan-off mode depends on ambient temperature and PoE load. Check your model's limits before closing it inside a cabinet or ceiling space.

Frequently asked questions

Does the NETGEAR M4250-12M2XF have PoE?+

No. Its twelve 2.5G copper ports and two SFP+ uplinks carry data only.

What speeds do the M4250-12M2XF copper ports support?+

100 Mbps, 1 Gbps and 2.5 Gbps on each of the twelve RJ45 ports.

How deep is the M4250-12M2XF?+

100 mm (about 3.9 in.), with a 440 mm width and 1U height, and it weighs 1.74 kg.

Can the M4250-12M2XF run fanless?+

Yes, with up to four 2.5G ports in use in each half of the switch and no SFP+ modules, at 25 C. Otherwise Quiet mode runs at about 28.5 dBA.

How do I open the M4250 AV interface?+

Browse to the switch's IP address followed by :8080. The standard IT web interface is on the normal port.

Which audio protocols do M4250 switches support out of the box?+

Dante, Q-SYS, AES67 and AVB profiles are built in, and AVB supports up to 256 streams per switch.

Can the M4250 run with its fans off?+

Yes on most models, when the ambient temperature and PoE load are low enough. The switch also has Quiet and Cool fan modes, and the M4250-9G1F-PoE+ has no fans at all.

Plan this av network switch in your rack

The M4250-12M2XF is in the Netgear library for DaMatrix, with every port mapped so you can drag it into a rack, patch it and print the documentation.

Related Netgear devices

Summarized from the NETGEAR M4250 Series AV Line Managed Switches Datasheet. This page is a quick reference; check the full manual for safety warnings and model-specific limits.

Manufacturer names and trademarks belong to their respective owners. Device libraries are provided for identification and compatibility purposes and do not imply affiliation, sponsorship, or endorsement.