Device guide · Rack server

Dell PowerEdge R760: rear panel, ports and setup guide

The PowerEdge R760 is a 2U, two-socket rack server for 4th and 5th Gen Intel Xeon Scalable processors, with 32 DIMM slots, up to eight PCIe slots and up to 24 front drives. Click any port on the rear panel below to see what it does, then read on for the specs, power supply choices, setup keys and LED codes.

  • 2U rack server
  • 2 x 4th/5th Gen Xeon
  • 32 DIMM slots
  • Up to 24 x 2.5 in.
  • 8 PCIe slots
  • iDRAC9
Rear panel, drawn to scaleInteractive
Server - PowerEdge R760 (rear, 2U) Riser 1 BOSS Riser 3 Riser 2 Riser 4 OCP PSU 1: IEC C14 mains inlet NIC 1: RJ45 (plain jack) NIC 2: RJ45 (plain jack) iDRAC9: RJ45 (plain jack) USB 2.0: USB-A USB 3.0: USB-A VGA: VGA (15-pin D-sub)VGA PSU 2: IEC C14 mains inlet
Dell PowerEdge R760 rear panel (standard air-cooled configuration with four risers). Click a port to identify it.
Get it in DaMatrix

PowerEdge R760 specifications

ModelDell PowerEdge R760
Form factor2U rack server
ProcessorsUp to two 4th Gen Intel Xeon Scalable or Xeon Max, or 5th Gen Intel Xeon Scalable
Memory32 DDR5 RDIMM slots, up to 8 TB with two processors (4800 MT/s on 4th Gen, 5600 or 6400 MT/s on 5th Gen)
Front drives12 x 3.5 in. SAS/SATA, 8, 16 or 24 x 2.5 in. SAS/SATA/NVMe, or 16 x EDSFF E3.S NVMe
Rear drives (optional)2 or 4 x 2.5 in., or 4 x EDSFF E3.S
BootOptional BOSS-N1 with two M.2 NVMe SSDs in hardware RAID
ExpansionUp to 8 PCIe slots on four risers (six full-length, two low-profile)
NetworkingOptional 2 x 1 GbE LOM, optional OCP 3.0 card up to 2 x 100 GbE
Rear portsiDRAC9 RJ45, USB 3.0, USB 2.0, VGA, optional serial card
Front portsUSB 2.0, iDRAC Direct (micro-USB), VGA
Power suppliesTwo hot-swap PSUs from 700 W to 3200 W, AC, HVDC or -48 V DC
Dimensions86.8 mm (3.41 in.) high, 434 mm (17.08 in.) wide, 700.7 mm (27.58 in.) ear to rear wall
WeightUp to 36.1 kg (79.58 lb) fully loaded
Operating temperature50 to 95 F (10 to 35 C) standard

Every port on the rear panel, explained

Click a card to light up those ports on the panel above.

2 LOM network ports2 on the panel

Two 1 GbE RJ45 ports on the optional LAN on Motherboard (LOM) card, at the left of the lower rear I/O.

The link light is green at full speed and amber at a lower speed; the activity light blinks green when data moves.

iDRAC9 management port1 on the panel

The dedicated Ethernet port for iDRAC9. Patch it to your management network to power the server on and off, open the remote console and update firmware from anywhere.

USB 2.0 and USB 3.02 on the panel

Two stacked USB-A ports: the top one is USB 2.0 and the bottom one USB 3.0. The front has another USB 2.0 port plus a micro-USB iDRAC Direct port for a laptop.

VGA video1 on the panel

A 15-pin VGA port driven by the integrated Matrox G200 (up to 1920 x 1200). There is also a VGA port on the front.

Power supplies2 on the panel

PSU 1 sits at the lower left of the rear and PSU 2 at the lower right. See power supplies for the options and the cord each one takes.

Also on the back

  • OCP NIC slot: takes an optional OCP 3.0 card with 1 GbE x 4, 10 GbE x 2 or x 4, 25 GbE x 2 or x 4, or 100 GbE x 2. You can run the LOM card, the OCP card or both.
  • Risers 1 to 4: riser 1 holds slots 1 and 2, riser 2 slots 3 and 6, riser 3 slots 4 and 5, and riser 4 slots 7 and 8. Some configurations replace slots with rear drive modules or liquid cooling.
  • BOSS module: the boot module between risers 1 and 3, holding two M.2 NVMe SSDs.
  • System ID button: press to flash the ID light so you can find the server in the rack. Hold more than 5 seconds during a hung POST for BIOS progress mode, or more than 15 seconds to reset the iDRAC.
  • Optional serial port: a 9-pin card that installs like an expansion slot bracket.

PowerEdge R660 power supplies

PSUInputCordHeat (max)
700 W Titanium200 to 240 V AC or 240 V DCC132625 BTU/hr
800 W Platinum100 to 240 V AC or 240 V DCC133000 BTU/hr
1100 W Titanium100 to 240 V AC or 240 V DCC134100 BTU/hr
1400 W Platinum or Titanium100 to 240 V AC or 240 V DCC135250 BTU/hr
1400 W Titanium 277 V277 V AC or 336 V HVDC277VAC/HVDC5250 BTU/hr
1800 W Titanium200 to 240 V AC or 240 V DCC156750 BTU/hr
2400 W Platinum100 to 240 V AC or 240 V DCC199000 BTU/hr
2800 W Titanium200 to 240 V AC or 240 V DCC2110500 BTU/hr
3200 W Titanium 277 V277 V AC or 336 V HVDC277VAC/HVDC12000 BTU/hr
1100 W DC-48 to -60 V DCC134265 BTU/hr

On 100 to 120 V circuits the 2400 W unit drops to 1400 W and the 1100 W and 1400 W units drop to 1050 W. The 1800 W unit can use a C13 cord with a C14 to C15 jumper, and the 2800 W unit a C19 cord with a C20 to C21 jumper.

Both PSUs must be the same type, wattage and label. Older-generation PowerEdge PSUs don't work here even at the same rating. If they mismatch, replace the one that is blinking.

PSU handle lightWhat it means
GreenPower connected and the PSU is working
Blinking amberProblem with the PSU
OffNo power connected
Blinking greenPSU firmware updating: don't unplug it
Blinks green 5 times, then offHot-added PSU doesn't match the other one

First boot: setup keys and iDRAC

F2
System Setup
F10
Lifecycle Controller
F11
Boot Manager
F12
PXE boot
  1. Patch the iDRAC9 port to your management network.
  2. If the server has the LCD bezel, open Setup, then iDRAC, and pick DHCP or a static IP. View, then iDRAC IP shows the address.
  3. No bezel? Plug a laptop into the front iDRAC Direct micro-USB port with a cable no longer than 3 ft.
  4. Check the information tag on the front for the iDRAC default password if your server shipped with secure default access.

PowerEdge R660 LED codes

System health / ID lightWhat it means
Solid bluePowered on and healthy
Blinking blueSystem ID mode is on
Solid amberFail-safe mode
Blinking amberA fault: check the System Event Log

The five status lights on the left control panel (drive, temperature, electrical, memory and PCIe) turn solid amber when that part of the system has an error.

On the optional LCD bezel the backlight is white when everything is normal and amber with an error code when something needs attention, even with the server off.

Memory and drives

RDIMM (4th Gen Xeon)Max, one processorMax, two processors
16 GB single rank256 GB512 GB
32 GB dual rank512 GB1 TB
64 GB dual rank1 TB2 TB
128 GB quad rank2 TB4 TB
256 GB octa rank4 TB8 TB

With 5th Gen Xeon, 96 GB RDIMMs are also supported (up to 3 TB with two processors) and memory runs at 5600 or 6400 MT/s. DDR4 is not supported and DIMM slots are not hot-pluggable. Front drives come in 3.5 in., 2.5 in. or EDSFF E3.S layouts, with optional rear drive modules.

Rack and room requirements

  • Standard operation is 50 to 95 F (10 to 35 C) out of direct sunlight, with the limit dropping about 1.8 F for every 1,000 ft above 2,950 ft.
  • Maximum operating altitude is about 10,000 ft (3,050 m).
  • The depth is about 27.6 in. ear to rear wall and about 29 in. to the PSU handles, so check your rack depth.

Frequently asked questions

How much memory does the PowerEdge R760 support?+

Up to 8 TB with two processors, using 32 DDR5 RDIMMs of 256 GB. One processor supports up to 4 TB.

What power supplies fit the Dell R760?+

Two matching hot-swap PSUs: 700, 800, 1100, 1400, 1800, 2400, 2800 or 3200 W, with AC, 277 V or HVDC, and -48 V DC options.

How do I reset the iDRAC on an R760?+

Hold the system ID button on the front or back for more than 15 seconds, unless that option is disabled in iDRAC setup.

How many PCIe slots does the R760 have?+

Up to eight, on four risers: six full-length and two low-profile.

How many drives does the R760 hold?+

Up to 24 x 2.5 in. or 12 x 3.5 in. at the front, or 16 EDSFF E3.S drives, plus optional rear modules with 2 or 4 more.

What does a blinking amber light on the R760 mean?+

On the system health light it means a fault; check the System Event Log. On a PSU handle it means a problem with that power supply.